Cylinder Class |
Flange Type |
Sealing |
Special Bolting |
"For Orifice" Bolting |
Orifice Plate Thickness Required | |
|
13-1/2JG:J:M |
O-ring |
SA-105 |
Fatigue Fighter |
Option |
1/2" with o-ring groove | |
|
17-1/4R:RJ:H:E 19-1/2R:RJ:H:E |
O-ring |
SA-105 |
Fatigue Fighter |
Option |
1/2" with o-ring groove | |
|
22-1/2H:E |
Gasket |
SA-516 Gr70 and SA-53 |
Fatigue Fighter |
Not Avail |
Not Applicable | |
|
17-7/8K:T:C:D:Z:U 20-1/8K:T:C:D:Z:U 22K:T:C:D:Z:U |
Flexitallic Gasket |
SA-516 Gr70 |
Fatigue Fighter |
Option |
3/8" | |
|
24-1/8K:T:C:D:Z:U 26-1/2K:T:C:D:Z:U |
Flexitallic Gasket |
SA-516 Gr70 |
Fatigue Fighter |
Option |
3/8" | |
|
19BL:VL:BM:VM |
Flexitallic Gasket |
SA-516 Gr70 |
Fatigue Fighter |
Included |
Included | |
|
Higher Pressure Cylinder Class (refer to Databook) |
Taper-Lok Seal Ring |
SA-350 LF2 |
Studs and Nuts |
Included |
Included | |
|
1-3/4SG-FS-HE 2-1/2SG-FS-HE |
O-Ring |
Fitting By Packager |
None |
Not Available |
Not Available |
Dual nozzle flanges are used on medium sized cylinders where there are two separate nozzles for suction, and two separate nozzles for discharge. These nozzles are weld neck flanges and need to be butt welded to nozzle piping between the flange and the pulsation vessel body. These nozzles are not standard ANSI flange sizes. The bolting is high strength fatigue fighter bolts, and the sealing is accomplished with an o-ring. When orifices are required, Ariel can provide longer bolting and an extra o-ring ("for orifice" option).
Racetrack flanges are used on the larger low pressure cylinders, 22-1/2H and E. The bolting is high strength fatigue fighter bolts, and the sealing is accomplished with a gasket. The flange nozzle is designed to weld directly to the pulsation vessel body or to a transition piece.
Peanut flanges are used on the larger cylinder classes. These cylinders have two separate flow areas like the dual nozzle cylinders, but the flanges are connected together resembling the shape of a peanut. The flanges are plate material ready for welding the pulsation vessel nozzle piping, two nozzles per flange. The bolting is high strength fatigue fighter bolts, and the sealing is accomplished with flexitallic gaskets. When orifices are required, Ariel can provide longer bolting and an extra flexitallic gasket ("for orifice" option). The flanges need to be welded to the nozzle piping between the flange and the pulsation vessel body. The Customer must specify either butt or fillet weld style flanges at time of order.
Taper-Lok flanges are used on higher pressure cylinders. Ariel provides a standard length Taper-Lok nozzle. If longer nozzle length is required to reach the appropriate pulsation vessel height, these flanges can be returned to a local Taper-Lok representative for longer nozzles. The Taper-Lok orifice plates are provided with each flange assembly. The orifice plates have a minimum bore and require drilling to the orifice bore by the Packager.
When stainless steel Taper-Lok flanges are required by the Client or Packager (such as on carbon dioxide applications) Ariel will provide the studs and nuts and a deduct for the carbon steel flange parts. The Packager can procure the stainless steel flange, two seal rings and the orifice plate directly from Taper-Lok.
Taper-Lok flanges include an orifice plate with minimum bore. Final bore dimensions for all orifice plates to be machined by the Packager. Refer to the outline drawings for maximum bore limits.
SAE Straight Thread (Fitting Provided by Packager)
The 1-3/4SG-FS-HE and 2-1/2SG-FS-HE cylinder classes utilize an SAE o-ring style connection at the cylinder for gas inlet and discharge. These cylinders are most commonly fit up with tubing. The SAE o-ring fittings for tubing fitting can be found at a local Parker Hannifin distributor, Parker Seal-Lok O-Ring Face Seal Tube Fitting part number 16 F5OLO.
If piping will be utilized rather than tubing, a Grayloc hub to SAE adapter can be found at a local Grayloc distributor, drawing number H600307-1310. Care must be taken that an understanding of the use of Grayloc hubs is known prior to incorporating a Grayloc hub pipe system.
Code Calculations:
Code calculations for the special flanges are available on the Ariel website.
Standard materials of construction for these special flanges are carbon steel. Flange materials are suitable for NACE construction once suitable bolting is provided.
Dual Nozzle Flange SA-105
Racetrack Flange SA-516 Gr 70 and SA-53
Peanut Flange SA-516 Gr 70
Taper-Lok SA-350 LF2 suitable for -50 F
304L and 316L stainless steel materials are available options for the dual nozzle flanges and peanut flanges.
17-4PH bolting may lower available MAWP on some cylinders, specifically the 17-7/8K,T,C,D,Z,U Class cylinders and some KBB:V cylinders. Refer to the Ariel Databook.
Steel orifice plates for suction or discharge are commonly used for pulsation attenuation. Orifices are to be provided by the Packager. Longer bolts and extra o-rings / gaskets are available as a "for orifice" option when orifice plates are used (not applicable to welded in orifice plates).
Ariel encourages the use of orifice plates of specific thickness due to the special bolting types and lengths used in the "for orifice" bolting option provided by Ariel. The dual nozzle flanges require the use of o-rings rather than gaskets. The o-ring groove dimensions for the orifice plates are defined in the special flange outline drawings.
Dual Nozzle Flanges 1/2" orifice plate with o-ring groove
Peanut Flanges 3/8" orifice plate and gasket
Taper-Lok flanges include an orifice plate with minimum bore. Final bore dimensions for all orifice plates to be machined by the Packager. Refer to the outline drawings for maximum bore limits.
Ariel
Corporation Application Manual
11 November 2011